Connection/MODBUS_RS232.pm untested

filter: Statementstmt 0.0% 0 / 33 Branchbran 0.0% 0 / 2 Conditioncond 0.0% 0 / 3 MC/DCmcdc 0.0% 0 / 2 Subroutinesub 0.0% 0 / 7 Podpod 0.0% 0 / 2 totaltotal 0.0% 0 / 49 CC 2 SCAR 11.0
CC
2
Cov
0%
Query
6.0
new
2.0
BEGIN
2.0
CRAP 3.0
1 package Lab::Connection::MODBUS_RS232;
2 #ABSTRACT: RS232/RS485 MODBUS RTU connection
3 $Lab::Connection::MODBUS_RS232::VERSION = '3.899';
4 use v5.20;
5  
6 use strict;
7 use Scalar::Util qw(weaken);
8 use Time::HiRes qw (usleep sleep);
9 use Lab::Exception;
10  
11 our @ISA = ("Lab::Connection");
12  
13 our %fields = (
14 bus_class => 'Lab::Bus::MODBUS_RS232',
15 wait_status => 0, # sec;
16 wait_query => 10e-6, # sec;
17 read_length => 1000, # bytes
18 );
19  
20 sub new {
21 my $proto = shift;
22 my $class = ref($proto) || $proto;
23 my $self = $class->SUPER::new(@_)
24 ; # getting fields and _permitted from parent class
25 $self->${ \( __PACKAGE__ . '::_construct' ) }(__PACKAGE__);
26  
27 return $self;
28 }
29  
30 # this does not really make sense for MODBUS, as there are no "commands" and "responses"
31 # disable for the time being
32 # maybe makes sense: write value to one address, wait, read from another address.
33 sub Query {
34 my $self = shift;
35 my $options = undef;
36 if ( ref $_[0] eq 'HASH' ) { $options = shift }
37 else { $options = {@_} }
38  
39 warn
40 "Query is not implemented (and makes no sense) for MODBUS connections. Use Read. Ignoring.\n";
41 return undef;
42 }
43  
44 # return undef unless $self->slave_address($self->config()->{'slave_address'});
45 # # check the configuration hash for a valid bus object or bus type, and set the bus
46 # if( defined($self->config()->{'Bus'}) ) {
47 # if($self->_checkbus($self->config()->{'Bus'})) {
48 # $self->Bus($self->config()->{'Bus'});
49 # }
50 # else {
51 # warn('Given Bus not supported');
52 # return undef;
53 # }
54 # }
55 # else {
56 # if($self->_checkbus($self->config()->{'ConnType'})) {
57 # my $ConnType = $self->config()->{'ConnType'};
58 # my $Port = $self->config()->{'Port'};
59 # my $slave_address = $self->config()->{'slave_address'};
60 # my $Interface = "";
61 # if($ConnType eq 'MODBUS_RS232') {
62 # $self->config()->{'Interface'} = 'RS232';
63 # $self->Bus(new Lab::Bus::MODBUS_RS232( $self->config() )) || croak('Failed to create bus');
64 # #$self->Bus(eval("new Lab::Bus::$ConnType( $self->config() )")) || croak('Failed to create bus');
65 # }
66 # else {
67 # warn('Only RS232 bus type supported for now!\n');
68 # return undef;
69 # }
70 # }
71 # else {
72 # warn('Given Bus Type not supported');
73 # return undef;
74 # }
75 # }
76  
77 #
78 # Nothing to do, Read, Write, Query from Lab::Connection are sufficient.
79 #
80  
81  
82 1;
83  
84 __END__